Karl Fischer moisture analyzer YT-KF1-Shandong Yuntang Intelligent Technology Co., Ltd

WhatsApp:
+86 18866361895

Karl Fischer moisture analyzer YT-KF1

model:YT-KF1

The trace moisture analyzer uses the Karl Fischer titration principle and advanced microcomputer circuits to determine the content of trace moisture in liquids and solids with diff···

  technical support

Yuntang Technology

One click access to quotation WeChat Scan Code Add Technical Engineer

WhatsApp:+86 18866361895

WeChat:+86 17865361250

Email:yuntang@foxmail.com

close

Details

Related Cases

The trace moisture analyzer uses the Karl Fischer titration principle and advanced microcomputer circuits to determine the content of trace moisture in liquids and solids with different properties. For solids that are insoluble in reagents, as well as substances that react chemically with reagents or easily contaminate electrodes, corresponding solid and liquid samplers can be used for indirect measurement.

This instrument has the advantages of high measurement accuracy, fast analysis speed, wide range of use, stability and reliability, and simple operation. Widely used in industries such as electricity, petroleum, chemical, pesticide, and medicine. The sample measurement process is automatically controlled by the instrument, with stirring and measurement completed in about 60 seconds, and the measurement results are directly displayed; Fully sealed titration cell bottle, avoiding contact between reagents and people, and also avoiding the influence of environmental humidity;

Technical parameters:

Display system: LED five digit decimal number

Titration method: Electric titration method (Coulombic analysis method)

Electrolytic current: Automatic control of electrolytic current (maximum 400MA)

Frequency: 50Hz ± 5Hz

Measurement range: 0.0001% (1ppm) to 100%

Titration rate: 0.6mg/min (maximum)

Sensitivity threshold: 0.1ugH20

Applicable ambient temperature: 5-40oC

Power supply: AC220V ± 10%

Accuracy: 10ug~1mgH20; ± 3ug>1mgH2O: RSD<0.3% (excluding injection error)

Our products meet the following standards

1. GB/T7600 "Determination of Moisture Content in Operating Transformer Oil (Coulombic Method)

2. GB6283 "Determination of Moisture Content in Chemical Products - Karl Fischer Method (General Method)"

3. SH/T0246 "Determination of Water Content in Light Petroleum Products (Electricity Method)"

4. SH/T0255 "Method for determination of moisture content in additives and lubricating oils containing additives (electric method)"

5. GB/T11133 "Determination of Water Content in Liquid Petroleum Products (Karl Fischer Method)"

6. GB/T7380 "Determination of Moisture Content of Surfactants (Karl Fischer Method)"

7. GB10670 "Determination of Trace Moisture in Fluoromethane for Industrial Use by Karl Fischer Method"

8. GB/T606 Chemical reagents General method for determination of moisture Karl Fischer method

9. GB/T8350 "Denaturated Fuel Ethanol"

10. GB/T8351 "Ethanol gasoline for vehicles"

11. GB/T3776.1 "Method for determination of moisture content of pesticide emulsifiers"

12. GB/T6023 Determination of Trace Moisture in Industrial Butadiene by Karl Fischer Coulombic Method

13. GB/T3727 Determination of Trace Water in Ethylene and Propylene for Industrial Use

14. GB/T7376 Determination of Trace Moisture in Fluorinated Alkanes for Industrial Use

15. GB/T18619.1 Determination of water content in natural gas Karl Fischer Coulomb method

16. GB/T512 "Method for determination of moisture content in lubricating grease"

17. GB/T1600- Method for determination of moisture content in pesticides

18. GB/T11146 Determination of Water Content in Crude Oil (Karl Fischer Coulombic Method)

19. GB/T12717 "Test Methods for Acetic Esters for Industrial Use"

20. GB/T5074 Determination of moisture content in coking products

21. GB/T18826 Industrial 1,1,2-tetrafluoroethane (HFC-134a)

22. Meet the technical requirements of the National Pharmacopoeia for determining the moisture content in drugs using the Karl Fischer method

23. GB/T260 standard petroleum products - Determination of moisture content


Previous article:Solvent moisture detector YT-KF2 Next article:没有了!
Contact Us

WeChat:+86 17865361250

WhatsApp:+86 18866361895

Email:yuntangzhineng@foxmail.com

Copyright @ 2019-2022 Shandong Yuntang Intelligent Technology Co., Ltd All Rights Reserved. Copyright Source manufacturer of pesticide residue detector, food detector, bacteria detector

Contact   WeChat atp荧光检测仪_微生物细菌检测仪_atp检测仪器 厂家 价格 -云唐科技

Professional Food Testing Engineer

24-hour online service

Submit requirements and quickly recommend suitable products for you

Technical consulting services, instrument price lists, and online answers to industry solutions.
微信咨询 微信咨询

WhatsApp

+86 18866361895
微信咨询 微信咨询

WeChat

微信咨询
回到顶部 回到顶部

TOP

liuyan  Leave us a message