model:YT-YT10
This instrument is based on standards such as GB/T 18854-2002 (ISO11171-1999). Developed using the principle of light blocking counting, it fully complies with the corresponding na···
Yuntang Technology
One click access to quotation WeChat Scan Code Add Technical EngineerWhatsApp:+86 18866361895
WeChat:+86 17865361250
Email:yuntang@foxmail.com
closeDetails
Picture and Text Introduction
Related Cases
This instrument is based on standards such as GB/T 18854-2002 (ISO11171-1999). Developed using the principle of light blocking counting, it fully complies with the corresponding national military standards, national standards, and international standards. It can provide fast, accurate, reliable, and reproducible detection results and complete pollution monitoring and analysis reports, suitable for detecting particle pollution levels in hydraulic oil, lubricating oil, fire-resistant oil, insulation oil, and turbine oil. It can be widely used in aviation, aerospace, power, petroleum, chemical, transportation, ports, metallurgy, machinery, automobile manufacturing and other fields.
main features
Adopting the counting principle of photoresist (shading) method developed by the International Hydraulic Standards Committee
High precision laser sensor with a wide testing range, stable performance, low noise, and high resolution
Adopting high-pressure injection pump sampling method, the sampling volume can be set by oneself, the injection speed is stable, and the sampling accuracy is high
The injection system combining positive and negative pressure can achieve sample degassing and is suitable for testing samples with different viscosities
Equipped with a built-in pressure sensor, it can directly set the pressure value and automatically determine the pressure inside the cabin to ensure safety
The host is equipped with an air purification system to ensure that testing is not contaminated, with a high degree of integration to avoid secondary pollution caused by the airtightness of the connection between the air pump and the testing system
Built in multiple calibration curves, compatible with all commonly used domestic and international standards for calibration
Built in GJB-420A、GJB-420B、NAS1638、GB/T14039、ISO4406、SAE4059cpc、SAE4059F、SAE749D、ГOCT17216、QC/T29104、JB/T9737、DLT432、HH005-2018 Waiting for more than ten commonly used standards
L supports custom standard testing, allowing for naming and grading of custom standards
According to customer requirements, up to 64 detection channels can be set up simultaneously
Built in data analysis system, one test can provide all standard test data and pollution levels
L can perform cleaning detection, pre-set target cleaning requirements particle concentration, display cleaning status in real-time during the cleaning process, and automatically stop when the requirements are met
Built in viscosity, moisture, and temperature sensor modules provide viscosity, moisture saturation, ppm values, and temperature reference values (optional) while accurately testing particle distribution
The particle size can be set arbitrarily, with nearly 10000 built-in particle sizes for easy particle size analysis
Various sampling containers such as standard sampling bottles or cups can be used to meet the testing requirements of different industries
Fully functional 7-inch color touch screen operation, foldable button design, supports both Chinese and English interfaces, easy and convenient operation
L can perform manual, automatic, and semi counting calibration
L has RS232 interface, supports 485 communication, and can be connected to a computer or laboratory platform for data processing
L has massive data storage and printing functions, and supports USB storage. The data already stored on the machine can be exported to a USB drive
L has 5 or more account settings and allows for individual setting of operator permissions
TECHNICAL INDEX
Light source: semiconductor laser
Particle size range: 0.8 μ m~600 μ m (calibrated according to ACFTD ranging from 1 to 100 μ m or ISO MTD ranging from 4 to 70 μ m (c))
L detection channels: 8-64 channels are optional (default 64 at the factory), and the particle size can be set arbitrarily
Sensitivity: 0.8 μ m (ISO4402) or 3 μ m (c) (GB/T18854, ISO11171)
Resolution: better than 6%
Repeatability: RSD<2%
Sample viscosity testing: ≤ 650cSt (if the viscosity is too high, it can be tested by heating or dilution methods)
Sampling volume: 0.2~6000mL, with an interval of 0.1mL
Sampling accuracy: better than ± 0.2%
Sampling speed: 5~80mL/min
L pressure chamber: positive and negative pressure chamber device, realizing sample degassing and high viscosity sample detection
Maximum vacuum in the pressure chamber: 0.08Mpa
Maximum positive pressure of the pressure chamber: 1 Mpa
Maximum particle concentration: 12000~40000 particles/mL
Temperature (paid optional): Collection range: 1-100 ℃; Collection accuracy: 1 ℃
Water activity (paid optional): Collection range: 1-100% RH; Collection accuracy: 1% RH
Water content (paid optional): Collection range: 1~360ppm; Collection accuracy: 1ppm
Test sample temperature: 0 ℃~80 ℃
Working temperature: -20 ℃~60 ℃
Storage temperature: -30 ℃~80 ℃
Power supply: 110~245V AC, 50/60Hz, 70W
Host size: 340mm × 410mm × 650mm
Air pump size: 180mm × 160mm × 220mm
Net weight of host: ≯ 23kg Net weight of air pump: ≯ 5.5kg
Comparison Table of Key Parameters of Desktop Particle Counter:
Parameter: YT10
Size: 340 × 410 × 650mm
Screen: 7-inch color touch screen
Custom testing standard: 64 channels, can add 1 set of standards
Calibration curve: Conventional curve, defined before leaving the factory
Information input method: keyboard input
Data output method: Built in printer with RS232, RS485, and USB interfaces, supporting standard Modbus communication
Data format: TXT text
System software: Can set operator account password permissions, edit sample names, etc
Number of accounts: 5
Memory: 1000 sets
Moisture viscosity temperature function: optional
Dynamic chart display:-
Parameter: YT20
Size: 340 × 310 × 615mm
Screen: Standard 10.4-inch Win10 tablet (optional Win10 or above system computer)
Custom testing standard: 64 channels, unlimited addition of standard quantity
Calibration Curve: Supports all curves, can be added by oneself, with no quantity limit
Information input methods: keyboard input, handwriting input
Data output method: Built in printer, also supports desktop printer, supports WiFi, Bluetooth, USB, etc
Data format: PDF, EXCEL
System software: Can set operator account password permissions, edit sample names, etc., supports personalized signatures
Number of accounts: Unlimited
Memory: Unlimited
Moisture viscosity temperature function: optional
Dynamic chart display:-
沧县人民检察院采购云唐检测设备
Shandong Yuntang dispatched technical backbone to Shiyan Agricultural Mall for on-site training
Biological toxicity testing equipment entering Southwest University of Petroleum
Zhuhai Haimiao Aquatic Products Import and Export Introduces Our Aquatic Product Quality Testing Instrument
South Petroleum University has introduced Shandong Yuntang Biological Toxicity Testing Instrument for scientific research and teaching purposes.
The Market Supervision Administration of Xishi District, Yingkou, Liaoning Province has introduced Yuntang Food Rapid Inspection Instrument
WeChat:+86 17865361250
WhatsApp:+86 18866361895
Email:yuntangzhineng@foxmail.com
Copyright @ 2019-2022 Shandong Yuntang Intelligent Technology Co., Ltd All Rights Reserved. Copyright Source manufacturer of pesticide residue detector, food detector, bacteria detector